• Jun 01, 2020 News!Papers published in Vol.10, No.2 have all received dois from Crossref.
  • May 15, 2020 News!Papers published in Vol.9, No.1-Vol.10, No.1 have all received dois from Crossref.
  • May 15, 2020 News!IJIEE Vol. 10, No. 2 issue has been published online!   [Click]
General Information
    • ISSN: 2010-3719 (Online)
    • Abbreviated Title: Int. J. Inf. Electron. Eng.
    • Frequency: Quarterly
    • DOI: 10.18178/IJIEE
    • Editor-in-Chief: Prof. Chandratilak De Silva Liyanage
    • Executive Editor: Jennifer Zeng
    • Abstracting/ Indexing : Google Scholar, Electronic Journals Library, Crossref and ProQuest,  INSPEC (IET), EBSCO, CNKI.
    • E-mail ijiee@ejournal.net
Editor-in-chief

 
University of Brunei Darussalam, Brunei Darussalam   
" It is a great honor to serve as the editor-in-chief of IJIEE. I'll work together with the editorial team. Hopefully, The value of IJIEE will be well recognized among the readers in the related field."

IJIEE 2013 Vol.3(5): 523-528 ISSN: 2010-3719
DOI: 10.7763/IJIEE.2013.V3.370

Design and Implementation of Capnograph for Laparoscopic Surgery

Daniel Santoso and Fransiscus Dalu Setiaji
Abstract— Capnography is a non-invasive method of monitoring the concentration of partial pressure of carbon dioxide. Nowadays, the application of capnography is a standard for general anesthesia. In this research, we design and implement sidestream capnograph based on microcontroller that can estimate the concentration of CO2 in the respiratory gases and measure respiratory rate. The accuracy of the prototype EtCO2 and RR has been verified relative to NT1D Series Handheld Vital Signs Monitor from Solaris Medical Technology Inc. in two chances of operation. The overall bias for EtCO2 based on relative verification between prototype and NT1D Series is 5.58% and -1.17% respectively whereas the overall bias for RR is -0.62 bpm and -0.29 bpm respectively. The correction feature to handle interference due to presence of gases such as sevoflurane, N2O and O2 is also implemented in the firmware.

Index Terms— End-tidal CO2 rate, sidestream capnograph.

The authors are with the Department of Electronics and Computer Engineering, Satya Wacana Christian University, 52nd – 60th Diponegoro Rd., Salatiga 50711, Indonesia (email: daniel.santoso@staff.uksw.edu)

[PDF]

Cite: Daniel Santoso and Fransiscus Dalu Setiaji, " Design and Implementation of Capnograph for Laparoscopic Surgery," International Journal of Information and Electronics Engineering vol. 3, no. 5, pp. 523-528, 2013.

Copyright © 2008-2021. International Journal of Information and Electronics Engineering. All rights reserved.
E-mail: ijiee@ejournal.net