• Jun 01, 2020 News!Papers published in Vol.10, No.2 have all received dois from Crossref.
  • May 15, 2020 News!Papers published in Vol.9, No.1-Vol.10, No.1 have all received dois from Crossref.
  • May 15, 2020 News!IJIEE Vol. 10, No. 2 issue has been published online!   [Click]
General Information
    • ISSN: 2010-3719 (Online)
    • Abbreviated Title: Int. J. Inf. Electron. Eng.
    • Frequency: Quarterly
    • DOI: 10.18178/IJIEE
    • Editor-in-Chief: Prof. Chandratilak De Silva Liyanage
    • Executive Editor: Jennifer Zeng
    • Abstracting/ Indexing : Google Scholar, Electronic Journals Library, Crossref and ProQuest,  INSPEC (IET), EBSCO, CNKI.
    • E-mail ijiee@ejournal.net
Editor-in-chief

 
University of Brunei Darussalam, Brunei Darussalam   
" It is a great honor to serve as the editor-in-chief of IJIEE. I'll work together with the editorial team. Hopefully, The value of IJIEE will be well recognized among the readers in the related field."

IJIEE 2015 Vol.5(2): 98-101 ISSN: 2010-3719
DOI: 10.7763/IJIEE.2015.V5.510

Microsystem in LTCC Technology to the Detection of Acetone in Exhaled Breath

Artur Rydosz
Abstract— An acetone is a well-known diabetes biomarker, since patients with diabetes tend to have higher acetone levels in their breath than healthy people. Exhaled acetone levels are usually in the range of 0.3-0.9 ppm (parts per million) for healthy subjects and over 3 ppm for patients with diabetes. Commercially-available gas sensors are under development for measuring samples at several tens ppm. Due to this fact, the microsystem with micropreconcentrator and sensor array is proposed as a solution that overcomes these limitations. The microsystem designed by author was manufactured in LTCC (Low Temperature Cofired Ceramics) technology. The microsystem based on micropreconcentrator structure as well as metal oxide gas sensors array. Acetone in diabetic breath was found to be higher than 1.11 ppm, while its concentration in normal breath was lower than 0.83 ppm.

Index Terms— Breath analysis, low temperature cofired ceramics (LTCC), exhaled acetone measurements, micropreconcentrators.

Artur Rydosz is with the Electronic Department, AGH University of Science and Technology, Av. Mickiewicza 30, 30-059 Krakow, Poland (tel.: 0048-12-6173039; fax: 0048-12-633-23-98; e-mail: artur.rydosz@agh.edu.pl).

[PDF]

Cite: Artur Rydosz, " Microsystem in LTCC Technology to the Detection of Acetone in Exhaled Breath," International Journal of Information and Electronics Engineering vol. 5, no. 2, pp. 98-101, 2015.

Copyright © 2008-2021. International Journal of Information and Electronics Engineering. All rights reserved.
E-mail: ijiee@ejournal.net